Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Sci Pollut Res Int ; 30(36): 85482-85493, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37389750

RESUMO

Grass uptake and phytoaccumulation factors of N-(n-butyl) thiophosphoric triamide (NBPT) and dicyandiamide (DCD) were quantified. Following the application of urea fertilizer treated with the inhibitors in Irish grassland, grass samples were collected at 5, 10, 15, 20, and 30 day time intervals following five application cycles. Uptake of NBPT by grass was below the limit of quantitation of the analytical method (0.010 mg NBPT kg-1). Dicyandiamide concentrations in grass ranged from 0.004 to 28 mg kg-1 with the highest concentrations measured on days 5 and 10. A reducing trend in concentration was found after day 15. The DCD phytoaccumulation factor was ranged from 0.004% to 1.1% showing that DCD can be taken up by grass at low levels when co-applied with granular urea. In contrast, NBPT was not detected indicating that grass uptake is unlikely when co-applied with granular urea fertilizer. The contrasting results are likely due to very different longevity of DCD and NBPT along with the much lower rate of NBPT, which is used compared with DCD.


Assuntos
Poaceae , Urease , Ureia , Nitrificação , Fertilizantes/análise , Inibidores Enzimáticos/farmacologia , Solo , Nitrogênio
2.
Molecules ; 26(10)2021 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-34068145

RESUMO

N-(n-butyl) thiophosphoric triamide (NBPT) is a urease inhibitor utilised in urea-based fertilizers. In Ireland, fertilizer treated with NBPT is applied to pasture to mitigate both ammonia and nitrous oxide emissions, but concerns arise as to the potential for residues in milk products. A quick ultrafiltration extraction and ultra-high performance liquid chromatography coupled with mass spectrometry triple quadrupole (UHPLC-MS/MS) quantitation method was developed and validated in this study. The method was applied in the analysis of samples collected from a field study investigating potential transfer of NBPT residues into milk. NBPT and NBPTo residues, were extracted from fortified milk samples and analysed on a UHPLC-MS/MS with recoveries ranging from 74 to 114%. Validation of the UHPLC-MS/MS method at low (0.0020 mg kg-1) and high (0.0250 mg kg-1) concentration levels in line with SANTE/12682/2019 showed overall trueness in the range of 99 to 104% and precision between 1 and 10%, RSD for both compounds. The limit of quantitation (LOQ) was 0.0020 mg kg-1 and other tested parameters (linearity, sensitivity, specificity, matrix effect, robustness, etc.) satisfied acceptance criteria. Stability assessment using spiked samples revealed the compounds were stable in raw and pasteurised milk for 4 weeks at -80 °C storage temperature. Maintaining samples at pH 8.5-9.0 further improved stability. Analysis of 516 milk samples from the field study found that NBPT and NBPTo concentrations were below the LOQ of 0.0020 mg kg-1, thus suggesting very low risk of residues occurring in the milk. The method developed is quick, robust, and sensitive. The method is deemed fit-for-purpose for the simultaneous determination of NBPT and NBPTo in milk.


Assuntos
Amidas/análise , Leite/química , Compostos Organofosforados/análise , Compostos Organofosforados/química , Solventes/química , Espectrometria de Massas em Tandem , Animais , Cromatografia Líquida de Alta Pressão , Fazendas , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...